| Contact Us | Bookmark Us |
|
Radon Gas Surveys |
| |
What NRP offers:
•Survey’s, test certificate, photos, reports.
•Remediation options
•Database recording
–Service
•6, 12 and 36 months, sampling.
•Detailed reports & updates with online access
•Independent verification with Track Etch |
 |
| |
 |
Radon Specialists
We specialise in geological radon risk assessment surveys for residential and commercial conveyancing and the construction industry. Depending on your location when building or extending your home your local authority will often ask for a Geological Radon Survey on your property. |
|
|
AIphaGUARD PQ2000
AlphaGUARD has become the instrument of choice by principal Radon laboratories worldwide as well as for use in the field under harsh environmental conditions. The instrument is light in weight and can be operated either from battery power or on line. The range of response of the top-of-the-line AIphaGUARD PQ2000 extends over six orders of magnitude (up to 2,000,000 Bq/m3.). |
 |
|
|
NRP BRE 250 & 293 Radon Survey Procedures
(Based on information from HPA. UK Radon, BRE, DEFRA)
DOMESTIC CUSTOMERS
- HPA/BGS new maps have highlighted housing stock in the UK that are in potentially high areas of Radon, the consumer can download a report which gives the risk factor of radon in their home and determine whether further investigation is required.
- In Areas where the readings are high which can be determined by either, previous 3 month etch track readings or by high radon probability from HPA/BGS map.
- Conduct BRE 250 Radon survey to determine ingress of Radon , utilisation of electronic meter as screening tool to confirm level of ambient radon is above action level, (As documented in BRE250) Utilise this data to instigate a 3 month etch track monitor.
- Complete BRE 250 with diagnosis of radon ingress
- Suggest preliminary remediation steps that can be undertaken reduce ingress as per BRE 250
- Complete remediation works
- Install Etch Track Monitors ( I unit upstairs one downstairs)
- Receive notification on long term reading
- Assess reading
- Provide remediation methods where applicable.
COMMERCIAL CUSTOMERS
- HPA/BGS new maps have highlighted buildings in the UK that are in potentially high areas of Radon, the consumer can download a report which gives the risk factor of radon in their workplace and determine whether further investigation is required.
- In Areas where the readings are high which can be determined by either, previous 3 month etch track readings or by high radon probability from HPA/BGS map.
- Conduct survey following advice from BRE 293 to determine ingress of Radon , utilisation of electronic meter as screening tool to confirm level of ambient radon is above action level, (As documented in BRE293) Utilise this data to instigate a 3 month etch track monitor.
- Complete BRE 293 with diagnosis of radon ingress
- Suggest preliminary remediation steps that can be undertaken reduce ingress as per BRE 293
- Complete remediation works
- Install Etch Track Monitors ( This will vary dependant on site)
- Receive notification on long term reading
- Assess reading
- Provide remediation methods where applicable.
|
| |
Download an actual BR 250 Survey Document & Suggested remediation  |
|
|
|
|
|